Art

ASTM F1869 PDF

Standard Test Method for Measuring Vapor Emission Rate (MVER) of Concrete Subfloor Using Anhydrous Calcium Chloride. Apparatus – the kit plus a gram. The applicable industry standard for this test, ASTM F, defined the scope of CaCl testing: “This test method covers the quantitative determination of the rate. Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Carbide.

Author: Kaziktilar Mocage
Country: Cape Verde
Language: English (Spanish)
Genre: Technology
Published (Last): 23 May 2014
Pages: 455
PDF File Size: 13.8 Mb
ePub File Size: 11.33 Mb
ISBN: 138-9-95300-679-3
Downloads: 23814
Price: Free* [*Free Regsitration Required]
Uploader: Mezitaxe

Learn how your comment data is processed. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Home to ASTM F1869

Concrete moisture vapor migrates from the bottom of concrete slabs to their surfaces in order to evaporate. This measurement is the equivalent weight of water evaporating from ft 2 of concrete surface in a 24—h period. In fact, moisture-plagued concrete slabs certified by ASTM F protocol proved to be a patterned and persistent challenge to the concrete flooring industry — so much so that industry professionals began to investigate the scientific integrity of the CaCl moisture test.

Link to Active This link will always route to the current Active version of the f18699. It will produce quantified results directly applicable to flooring manufacturer’s specifications.

Concrete moisture emission is a natural process driven by environmental conditions. In light of such research, the American Society for Testing and Materials made two changes to moisture measurement industry standards. astmm

  BATTLEFLEET GOTHIC ANNUAL 2002 PDF

Public Knowledge Base

All concrete subfloors emit some amount of moisture in vapor form. It is the responsibility of the user of this standard to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.

The CaCl moisture test produced data based on moisture vapor emission rate MVERthe quantitative indication of how many pounds of slab moisture evaporated from square feet of concrete over a hour period.

This is how concrete dries. The moisture vapor emitted from a concrete slab is measured in pounds.

The moisture vapor emission rate only reflects the condition of the concrete floor at the time of the test. This led to continued moisture problems when that moisture eventually reached a covered concrete surface where wstm could no longer evaporate.

Historical Version s – view previous versions of standard.

The Workman’s History of Calcium Chloride Testing (F) – ASTM F Information

The results obtained reflect the condition of the concrete floor surface at the time of testing and may not indicate future conditions. Therefore, the natural migration process of concrete moisture drying is influenced by environment.

All floor coverings are susceptible to failure from excessive moisture vapor emissions. The calcium chloride moisture test has f18699 the industry standard for making this determination and is a practical, well-established and accepted test of dynamic moisture. Your email address will not be published. CaCl tended to underestimate the true moisture conditions at the high end of the moisture spectrum, while it tended to overestimate the moisture conditions of older slabs.

  EBOOK SIRAH NABAWIYAH PDF

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as t1869 of the standard. Builders, then, made threshold floor covering decisions based on errant readings. Although builders continue to use the CaCl moisture test, post-installation moisture problems eventually redefined it as a test method worthy of scrutiny.

Submit a Comment Cancel reply Your email address will not be published. But their truth has entered a new era and the challenges of moisture emissions-based testing are becoming increasingly clear.

Work Item s – proposed revisions of this standard. Generally, high ambient RH slows concrete drying as the slab absorbs moisture vapor; low ambient RH causes concrete to emit moisture vapor. Where the challenge became clear was in determining whether the surface emission rate determined by desiccant weight gain truly reflected the moisture conditions deeper in the slab. The CaCl moisture test is a building 1f869 with lineage.

Concrete floor installers began using the calcium chloride CaCl moisture test back in the early s to conclude when a new concrete slab was fit for floor coverings. This site uses Akismet to reduce spam.

CaCl measured only the top one-half to three-quarters inch of the slab. At that point, it was safe to install floor covering over a concrete substrate.

Over decades, CaCl gained industry acceptance as a practical standard.